WAVE
I SERIES
OWNER'S MANUAL
|
| |
Please read all instructions
completely before you install or operate your new pump.
Save this manual for future reference.
|
|
General Specifications
Glass filled ABS
injection housing.
Motor-Industrial
Baldor Motor with TEFC for quiet operation.
WAVE I Series 115v
comes with 6ft. cord. For WAVE I Series 230v, please see instruction manual
on motor.
Important : Please
read the Baldor, AC Motor Installation Maintenance Instructions Handling.
|
|
WARNING
|
This
pump and motor unit should be installed by a qualified, licensed or certified
electrician or serviceman in accordance with all applicable state and local
codes and ordinances, and in accordance with the National Electrical Code.
Improper installation may create a mechanical or electrical hazard which
could cause damage to property and which could result in serious injury
or death.
In order to avoid serious injury or death, always disconnect power to the
motor, at the circuit breaker before servicing the pump.
|
INSTALLATION
Proper installation
of your WAVE Pump will help it to provide you with years of trouble free
service.
|
| |
| ..1. |
Position
the pump as near to the source and as low as is practical. Note: Exhibit
A and B on Best Ways to Install the Wave Pump. Be careful to install a check
valve when necessary. This will help avoid cavitations and maximize your
performance. |
| ..2. |
Protect
the motor from excessive heat and moisture. It is best to provide shade
from direct sun, and insure that it has proper ventilation. Excessive heat
will shorten the motor life and void the warranty. |
| ..3. |
Protect the motor against dirt, water and all foreign matter.
If the motor has been flooded, do not operate it until it has been checked
by an authorized motor technician, and has been found to be safe to operate.
If the motor is damaged by dirt, moisture, flood or corrosion it voids the
warranty. |
| ..4. |
Mount
the motor to a flat, stable base where it won't get submerged. |
| ..5. |
The
pump ports are 2" NPT female on both the suction and discharge ports. The
fittings used to connect to the housing should be plastic. (We have provided
you with unions, for better connection and easy installation.) All plumbing
lines should be self supported and properly aligned. This will prevent undue
stress to the housing. We recommend sealing the pipe joints with the unions
included, DO NOT use Teflon tape. |
|
ELECTRICAL
|
| ..1. |
Make
sure the power is disconnected at the breaker before wiring the motor.
|
| ..2. |
Make
sure that the motor is wired so that it matches the supply voltage (eg.
115 or 230 volt). If they do not match it will damage your motor and void
the warranty. |
| ..3. |
Use a
wire of adequate gauge to prevent electrical line losses. The use of heavier
gauge wire will allow the motor to run cooler and more efficiently, by eliminating
excessive voltage drop. |
| ..4. |
Make
sure all connections are clean and tight. Properly ground the motor. (There
is normally a green ground terminal located on the inside of the motor connection
box.). Make sure the ground wire is properly connected to an electrical
service ground. |
| ..5. |
The supply line and pump outlet should be permanently
connected to an adequately sized circuit. It is best to have a dedicated
circuit that won't suffer voltage drop from other loads. The wiring, fusing
and grounding must comply with the National Electrical code and local codes. |
|
CAUTION
|
| ..1. |
The
polished and lapped faces of the seal could be damaged if not handled with
care. |
| ..2. |
DO
NOT run the pump dry. |
|
|
|
SPECIALLY DESIGNED FOR KOI PONDS
|
|

|
| |
|
W AV E ..I
..S E R I E S
|
|
Limited
Warranty
|
| W.
Lim Corporation warrants its WAVE I Series centrifugal pumps to be free
of defects in material and/or workmanship at the time of purchase for a
period of one year. Prior to packaging, all WAVE Pumps have been tested
at 115v and 60 Hz for approximately 15 minutes to ensure good quality control.
In the event this product malfunctions within three years from the date
of purchase, the sole obligation of W. Lim Corporation will be to repair
or replace the product. To qualify for three years of warranty you must
return the warranty paper, and a copy of the receipt within 10 days, with
the date of purchase and the name of company that you purchased the pump
from. |
| |
|
THIS
LIMITED WARRANTY IS SUBJECT TO THE FOLLOWING CONDITIONS AND EXCLUSIONS:
|
| ..1. |
W. Lim
Corporation must perform all warranty repairs. Purchaser must retain the
purchase receipt and present it with the original copy of this certification
as proof of ownership and entitlement to warranty repairs. Unauthorized
repairs will not be compensated by W. Lim Corporation and are not the responsibility
of the company. If such repairs damage the product, such damage is not redeemable
under this warranty. |
| ..2. |
Problems
or damage resulting from failure to comply with instructions in the owner's
manual, improper plumbing and positioning, flooding, corrosion or salt build
up, incompatibility with fluid chemistry and running unit dry are not covered
under this warranty. Malfunction for any other reason-including but not
limited to misuse, negligence, accident, tampering with parts, incorrect
wiring, or improper installation- will not be redeemed under this warranty.
|
| ..3. |
If
the label, on the pump, has been tampered with or damaged, then the warranty
will be void. Likewise, if the pump has been opened, the warranty will be
void as well. |
| ..4. |
Due
to the different chemicals, temperature, conditions of the water, etc.
that are used and that may affect the condition of the seal, WAVE Pumps
seals are only limited to a 10 day guarantee.
|
| ..5. |
Purchaser
shall bear all shipping, packing, and insurance costs and all other costs,
excluding labor and parts necessary to effectuate repairs under this warranty. |
| ..6. |
Periodic
check-ups are not covered by this warranty. |
| ..7. |
This
is the sole and exclusive manufacturer's warranty. Any and all implied warranties,
including any warranties of merchantability and fitness for particular purpose,
shall have no greater duration than the duration period of the express written
warranty applicable to this product, and shall terminate automatically upon
the expiration of such duration period. Some states do not allow limitations
on how long an implied warranty lasts, so the above limitation may not apply
to you. No action shall be brought for breach of any express warranty subsequent
to the expiration of this express written warranty. Except as is otherwise
provided by applicable law, no action on a warranty implied at law, no action
on a warranty implied at law shall be commenced more than one year following
the date of purchase. |
| ..8. |
Incidental
and consequential damages (specifically including, but not limited to, damages
for loss of profits or damages relating to down time of people or equipment)
caused by malfunction, defect, or otherwise, and with respect to breach
of any express or implied warranty, are not the responsibility of W. Lim
Corporation, and, to the extent permitted by law, are hereby excluded both
for property damage and, to the extent not prohibited by applicable law,
for personal injury damage. Some states do not allow the exclusion or limitation
of incidental or consequential damages, so the above limitation or exclusion
may not apply to you. |
| ..9. |
The provisions
of this warranty are sever-able and if any provision shall be deemed invalid,
the remaining provisions shall remain in full force and effect.
|
| 10. |
Rights
under this warranty are not assigned without the express prior consent in
writing by W. Lim Corporation. Regardless of the terms of any consent in
writing, the assignees shall have no greater rights than his assignor had
against W. Lim Corporation. Any purported assignment without the consent
of the company shall be null and void. |
| 11. |
This
contract shall be governed by and in accordance with the laws of the state
of California. |
| 12. |
This limited warranty
is incorporated by reference into the contract of purchase for the products
supplied by W. Lim Corporation to purchase under said contract.
|
| |
Best
Ways to Install the Wave Pump
|
|
INSTALLATION ABOVE
WATER LEVEL (GROUND LEVEL)
To
install the WAVE Pump above water level, use a Check Valve between the
Settlement Tank & Leaf
Trap. The Check Valve must be at least 12" below the water level. The
Wave Pump pumps water
through the Biological Filter to the Waterfall Filter then back to the
pond.
|
|
|
| |
|
INSTALLATION
BELOW WATER LEVEL
To
install the WAVE Pump below the water level, you need a pump housing to
protect the WAVE
Pump, and the Leaf Trap from being flooded by rainwater. With the pump
housing in place, a Check
Valve is not necessary. Make sure you have a drain in the pump housing
when it rains. The WAVE
Pump pumps water through the Biological Filter to the Waterfall Filter,
then back to the pond.
|
|
|